logo.GIF (297 bytes)globepic.GIF (813 bytes)
 

 

Double Flier Armature Winder

MDF-4000 MR Millenium Retrofit

STANDARD FEATURES

  • New operator interactive VGA color monitor with mouse providing a graphical user interface, displayed in a windows environment. Includes replacement push buttons and mounting hardware.

  • IC-2000 Industrial Computer open architecture control system incorporating 'off-the-shelf' scaleable hardware including:

    • Pentium micro processor.

    • ISA industrial grade Bus.

    • Flash Drive for program storage (non-rotating).

    • 3.5in., 144Mbyte floppy disk drive for part parameter and production data backup.

    • Ethernet 10-Based-2 coaxial networking.

    • Centronics printer port.

    • NX real-time operating system providing a windowing environment, displaying and including; parameter storage for up to 1000 part configurations, operator selectable and graphically displayed production data, extended diagnostics through complete I/O status examination and fault prompting, setup utilities with wire tension and wind velocity profile viewing, and single keying of multiple languages.

  • New Brushless D.C. Servo Drive with absolute resolver and capable of obtaining flier speeds of 3,800 RPM in 250 milliseconds.

  • 40Mhz Digital Signal Processor (DPS) for motion control of the fliers and rotator motor positions.

  • Separate flier drive motor Accel and Decel settings with 'S' curve ramping for quick and smooth winding velocities.

  • UR-I Universal Rotator for precise, high speed index of armature including:

  • Herring bone belt, servo motor drive.

  • New input and servo breakout boards.

  • Industrial standard collet clamping design utilizing draw bar and commercially available collet.

  • ‘No-tool' adjustable, heavy duty wire clamp assemblies.

  • Collet retainer and draw bar assembly.

  • Collet.

  • Connecting pins for inner/outer shield assemblies.

  • Requires removal of tensioning meter.

  • Clean and repaint machine to customer’s specification.

  • Does not include new opto touch buttons.

  • New valves and output modules.

  • Alter inner and outer shield assemblies.

  • Accommodates a wire range of 0.08 to 1.29mm (38 to 16AWG).

  • Metric construction.

  • 12mm plug-in proximity switches.

  • EXACTROL Electronic Wire Tension Controller included in IC-2000 controls system.

  • Standard software includes generally accepted automotive-alpha and DIAMACON winding patterns on standard type armatures.

  • Software can include Snap-Away, ACCUTRIM, inner shield and pull back outer shield trimming.

  • Dynamic wire sensing mechanism to detect broken and/or depleted wire supply.

  • Engineering and documentation.

  • Installation at Globe Products Inc. included.

 

 

   

 

Machine Specifications

 Electrical Requirements

  • Standard 7. KVA; 208, 240, 380, 415, 480 and 600

  • Volts, 3-phase; 50/60 Hertz. 

Pneumatic Requirements

  • An air supply of 100 PSI (6.8 atm) with minimum

  • 9 CFM (255 liters/minute) is required to operate the machine.

  • A pressure regulator (supplied with the machine) will reduce the pressure to 80 PSI (5.5 atm) for the machine operation. 

Operating Environment

  • 40 degrees Fahrenheit (4 degrees Centigrade)

  • to 104 degrees Fahrenheit (40 degrees Centigrade).

 

 

 

Back to Armature Winding Machines